Applications and installation
These pumps with peripheral impeller are able to offer high pressure in relation to comparatively low powers and which have particularly steady operating curves.
For the correct functioning of the pump, use to pump clean water, or non-aggressive liquids only , without sand or other solid impurities.
They are qualified in domestic fitting, to increase the system pressure in aqueducts and for automatic water distribution by autocalve tanks and by hydrosphere units..
Pumps should be installed in a covered area, protected
against the weather.
Operating limitations
Liquid temperature up to 60℃
Ambient temperature up to 40℃
Total suction lift up to 9m
Continuous duty
Construction features
PUMP
Pump Body: Cast Iron
Impeller: Brass
Mechanical Seal: Carbon / Ceramic / Stainless Steel
MOTOR
Single Phase
Heavy Duty Continuous Work
Motor Housing: Aluminum / Steel-plate
Shaft: Carbon Steel / Stainless Steel
Insulation: Class B / Class F
Protection: IP44 / IP54
Cooling: External Ventilation